    • scottalanmillerS
      scottalanmiller @CCWTech
      last edited by

      @ccwtech said in Failed Global Drive:

      It's going to be replaced in the next few hours... but wanted to see if I could deal with a slow server issue in the meantime.

      Yank it out now. It's already failing and you don't want a spare with a RAID 5 array, so I'd pull it out and not replace it.

      CCWTechC 1 Reply Last reply Reply Quote 1
      • DashrenderD
        Dashrender
        last edited by

        How large is each drive?

        1 Reply Last reply Reply Quote 0
        • CCWTechC
          CCWTech
          last edited by

          600 GB

          DashrenderD 1 Reply Last reply Reply Quote 0
          • CCWTechC
            CCWTech @scottalanmiller
            last edited by

            @scottalanmiller said in Failed Global Drive:

            @ccwtech said in Failed Global Drive:

            It's going to be replaced in the next few hours... but wanted to see if I could deal with a slow server issue in the meantime.

            Yank it out now. It's already failing and you don't want a spare with a RAID 5 array, so I'd pull it out and not replace it.

            Why is a spare bad?

            coliverC scottalanmillerS 2 Replies Last reply Reply Quote 0
            • coliverC
              coliver @CCWTech
              last edited by

              @ccwtech said in Failed Global Drive:

              @scottalanmiller said in Failed Global Drive:

              @ccwtech said in Failed Global Drive:

              It's going to be replaced in the next few hours... but wanted to see if I could deal with a slow server issue in the meantime.

              Yank it out now. It's already failing and you don't want a spare with a RAID 5 array, so I'd pull it out and not replace it.

              Why is a spare bad?

              If you have a spare why not got RAID 10 instead of RAID 5? Faster and safer.

              1 Reply Last reply Reply Quote 2
              • scottalanmillerS
                scottalanmiller @CCWTech
                last edited by

                @ccwtech said in Failed Global Drive:

                @scottalanmiller said in Failed Global Drive:

                @ccwtech said in Failed Global Drive:

                It's going to be replaced in the next few hours... but wanted to see if I could deal with a slow server issue in the meantime.

                Yank it out now. It's already failing and you don't want a spare with a RAID 5 array, so I'd pull it out and not replace it.

                Why is a spare bad?

                Because it is RAID 5 and the spare automates the highest risk of total data loss. RAID 5 is not a super safe RAID technology, so the way to use it is to take a backup before replacing a failed drive as it is the replacement process that creates ~98% of the array failures. If you have a hot spare on a RAID 5, it means that the process of triggering that full data loss risk is instant, rather than giving the customer time to take a fresh backup.

                Also, a spare means that the disks were available for RAID 10, so both the reliability and the speed of RAID 10 are lost, but the cost is there.

                1 Reply Last reply Reply Quote 1
                • scottalanmillerS
                  scottalanmiller
                  last edited by

                  Hot Spare or a Hot Mess, why spares never are used with RAID 5.

                  1 Reply Last reply Reply Quote 0
                  • DashrenderD
                    Dashrender @CCWTech
                    last edited by

                    @ccwtech said in Failed Global Drive:

                    600 GB

                    At least the drives are fairly small, but there is still a noticeable percent of URE failure.

                    You're best bet would be to take an image of these system, wipe out the RAID 5, create a RAID 10 and restore the image.

                    You'll have a faster, safer system.

                    scottalanmillerS Reid CooperR 2 Replies Last reply Reply Quote 0
                    • scottalanmillerS
                      scottalanmiller @Dashrender
                      last edited by

                      @dashrender said in Failed Global Drive:

                      @ccwtech said in Failed Global Drive:

                      600 GB

                      At least the drives are fairly small, but there is still a noticeable percent of URE failure.

                      Yes, the overall risk isn't too bad. But the improper setup remains. It's like driving eratically, but very slowly. The risk of the crash is decently low, but fixing the eratic driving is still wise.

                      1 Reply Last reply Reply Quote 1
                      • Reid CooperR
                        Reid Cooper @Dashrender
                        last edited by

                        @dashrender said in Failed Global Drive:

                        You're best bet would be to take an image of these system, wipe out the RAID 5, create a RAID 10 and restore the image.

                        You'll have a faster, safer system.

                        That is what I would do. Fix it before replacing the spare in a bad way.

                        1 Reply Last reply Reply Quote 0
                        • CCWTechC
                          CCWTech
                          last edited by

                          New server soon so I'm going to keep it the same, but I am a Raid 10 fan, big time.

                          DashrenderD 1 Reply Last reply Reply Quote 0
                          • DashrenderD
                            Dashrender @CCWTech
                            last edited by Dashrender

                            @ccwtech said in Failed Global Drive:

                            New server soon so I'm going to keep it the same, but I am a Raid 10 fan, big time.

                            Test you backups then... Test, test - again.

                            As mentioned, RAID 5 at that size is not horrible, but definitely don't put the hot spare back in the system.

                            1 Reply Last reply Reply Quote 1
                            • CCWTechC
                              CCWTech
                              last edited by

                              Ok, will do. Thanks!

                              1 Reply Last reply Reply Quote 0
                              • scottalanmillerS
                                scottalanmiller
                                last edited by

                                Just put the new spare on top of the server or something - somewhere so it can be replaced the moment that you need it, but only with intent.

                                1 Reply Last reply Reply Quote 1