RAID10 - Two Drive Failure
-
@aaronstuder said in RAID10 - Two Drive Failure:
Drive are 1 and 3 are in "predictive failure" , I am assuming the pairs are 0+1 and 2+3.
Why?
-
@gjacobse said in RAID10 - Two Drive Failure:
@JaredBusch said in RAID10 - Two Drive Failure:
Predictive failure is not failure. Replace one at a time. to give the RAID card the most power to work on the individual resilver.
in my experience - you
never
replace more than one drive at a time...Ask me how I know.
In RAID 10, you always do if they are in different RAID 1 sets, always.
-
@scottalanmiller said in RAID10 - Two Drive Failure:
@aaronstuder said in RAID10 - Two Drive Failure:
Drive are 1 and 3 are in "predictive failure" , I am assuming the pairs are 0+1 and 2+3.
Why?
Why what? Assuming? Because he did not document and most hardware RAID controllers are not accessible except during the boot process.
-
@scottalanmiller said in RAID10 - Two Drive Failure:
@gjacobse said in RAID10 - Two Drive Failure:
@JaredBusch said in RAID10 - Two Drive Failure:
Predictive failure is not failure. Replace one at a time. to give the RAID card the most power to work on the individual resilver.
in my experience - you
never
replace more than one drive at a time...Ask me how I know.
In RAID 10, you always do if they are in different RAID 1 sets, always.
I completely disagree. Reason stated above.This is a predictive failure, not a failure. You will get a faster resilver of each mirror by doing them individually.
Of course I am assuming that the unit is in use and busy with normal system read/writes.
-
@JaredBusch said in RAID10 - Two Drive Failure:
I completely disagree. Reason stated above.This is a predictive failure, not a failure. You will get a faster resilver of each mirror by doing them individually.
Doesn't this put twice the amount of mileage on the array though? or no
-
@JaredBusch said in RAID10 - Two Drive Failure:
Predictive failure is not failure. Replace one at a time. to give the RAID card the most power to work on the individual resilver.
With mirrors RAID even the slowest RAID card won't feel the load of a straight copy. As long as they are not in the same RAID set, it'll be fastest and safest to do both at once.
-
@wirestyle22 said in RAID10 - Two Drive Failure:
@JaredBusch said in RAID10 - Two Drive Failure:
individual resilver.
Does this mean that the mileage is only applied to the new drive or it's just minimal in relation to the rest of the raid? Reason I ask is I always thought this put a lot of strain on the entire raid.
RAID 10 does not strain anything during a resilver, and the resilver operation only happens to a subset of the array, the overall array doesn't even know that it is happening.
-
@wirestyle22 said in RAID10 - Two Drive Failure:
@JaredBusch said in RAID10 - Two Drive Failure:
I completely disagree. Reason stated above.This is a predictive failure, not a failure. You will get a faster resilver of each mirror by doing them individually.
Doesn't this put twice the amount of mileage on the array though? or no
How could this even be conceived? FFS think. No matter which way you do it is is two RAID1 resilver operations. Same time or separate, that changes nothing.
-
@aaronstuder said in RAID10 - Two Drive Failure:
Some information I am reading says I need to take the drive "offline" first, is this true?
PowerEdge R720.
If killing one in predictive failure, yes you generally offline it first. But this depends on the controller in question, the server doesn't matter.
-
@wirestyle22 said in RAID10 - Two Drive Failure:
I'm assuming @JaredBusch's qualifier of "Predictive failure is not failure" means that the could possibly change if this were a failed drive?
If the drive has failed, then it is already offline.
-
@Dashrender said in RAID10 - Two Drive Failure:
@gjacobse said in RAID10 - Two Drive Failure:
@wirestyle22 said in RAID10 - Two Drive Failure:
@gjacobse said in RAID10 - Two Drive Failure:
@JaredBusch said in RAID10 - Two Drive Failure:
Predictive failure is not failure. Replace one at a time. to give the RAID card the most power to work on the individual resilver.
in my experience - you
never
replace more than one drive at a time...Ask me how I know.
That's very interesting. I have not really had to deal with drive failures actually.
I haven't kept up with the number of drive failures I have had over nearly 30 years. In all of my personal systems, I think I have had
one
.Work related,.. maybe all of three.
Wow, that's pretty small.
Personally, I've probably lost 3-4 drives. In businesses - well over 10.
And Scott has probably seen hundreds fail. Of course it all boils down to how many systems you see/support.
That's a pretty big factor. And how many drives are in them. 8,000 servers, over ten years, with a minimum of four drives in each... I saw a lot.
-
@JaredBusch said in RAID10 - Two Drive Failure:
@wirestyle22 said in RAID10 - Two Drive Failure:
@JaredBusch said in RAID10 - Two Drive Failure:
I completely disagree. Reason stated above.This is a predictive failure, not a failure. You will get a faster resilver of each mirror by doing them individually.
Doesn't this put twice the amount of mileage on the array though? or no
How could this even be conceived? FFS think. No matter which way you do it is is two RAID1 resilver operations. Same time or separate, that changes nothing.
Shawn Wallace aside, thanks for the info
-
@Dashrender said in RAID10 - Two Drive Failure:
@coliver said in RAID10 - Two Drive Failure:
@Dashrender said in RAID10 - Two Drive Failure:
@coliver said in RAID10 - Two Drive Failure:
@Dashrender said in RAID10 - Two Drive Failure:
@gjacobse said in RAID10 - Two Drive Failure:
@wirestyle22 said in RAID10 - Two Drive Failure:
@gjacobse said in RAID10 - Two Drive Failure:
@JaredBusch said in RAID10 - Two Drive Failure:
Predictive failure is not failure. Replace one at a time. to give the RAID card the most power to work on the individual resilver.
in my experience - you
never
replace more than one drive at a time...Ask me how I know.
That's very interesting. I have not really had to deal with drive failures actually.
I haven't kept up with the number of drive failures I have had over nearly 30 years. In all of my personal systems, I think I have had
one
.Work related,.. maybe all of three.
Wow, that's pretty small.
Personally, I've probably lost 3-4 drives. In businesses - well over 10.
And Scott has probably seen hundreds fail. Of course it all boils down to how many systems you see/support.
We have one or two fail every two-three months. Nothing crazy.
How many drives do you have?
A few hundred for now. Should be under 100 at the end of summer.
so you're losing around 1.5% of your drives per year... that seems a bit high, but my memory for the norm as published by google could be off. Plus your environment might not be as good as theirs.
That's low, actually.
-
@scottalanmiller said in RAID10 - Two Drive Failure:
@aaronstuder said in RAID10 - Two Drive Failure:
Some information I am reading says I need to take the drive "offline" first, is this true?
PowerEdge R720.
If killing one in predictive failure, yes you generally offline it first. But this depends on the controller in question, the server doesn't matter.
Obviously, depends on the controller, but the point of blind swap being standard choice for the SMB is that you simply swap the drives.
-
@JaredBusch said in RAID10 - Two Drive Failure:
@DustinB3403 said in RAID10 - Two Drive Failure:
@aaronstuder What raid controller do you have?
Exactly this. A real SMB system should be a hot plug. But we have no idea what you bought.
Even hot plug often requires you to offline a disk before you take it out for the system to be clear as to what is happening. ZFS is hot swap, but still requires that, for example.
-
@travisdh1 said in RAID10 - Two Drive Failure:
@gjacobse said in RAID10 - Two Drive Failure:
@JaredBusch said in RAID10 - Two Drive Failure:
Predictive failure is not failure. Replace one at a time. to give the RAID card the most power to work on the individual resilver.
in my experience - you
never
replace more than one drive at a time...Ask me how I know.
I solemnly swear that I've pulled the wrong drive to replace before . Made a RAID6 rebuild take a lot longer, and a RAID 10 freak out till a reboot happened. Restoring from backup was always an option at least.
That's the biggest risk... pulling the wrong drive or not being certain which arrays failed drives are in.
-
@JaredBusch said in RAID10 - Two Drive Failure:
@scottalanmiller said in RAID10 - Two Drive Failure:
@aaronstuder said in RAID10 - Two Drive Failure:
Drive are 1 and 3 are in "predictive failure" , I am assuming the pairs are 0+1 and 2+3.
Why?
Why what? Assuming? Because he did not document and most hardware RAID controllers are not accessible except during the boot process.
Why does he feel that they are in the sets that they are? I hear people say that all the time, and it turns out that most people say that without basing it on anything at all.
-
@JaredBusch said in RAID10 - Two Drive Failure:
@scottalanmiller said in RAID10 - Two Drive Failure:
@gjacobse said in RAID10 - Two Drive Failure:
@JaredBusch said in RAID10 - Two Drive Failure:
Predictive failure is not failure. Replace one at a time. to give the RAID card the most power to work on the individual resilver.
in my experience - you
never
replace more than one drive at a time...Ask me how I know.
In RAID 10, you always do if they are in different RAID 1 sets, always.
I completely disagree. Reason stated above.This is a predictive failure, not a failure. You will get a faster resilver of each mirror by doing them individually.
Of course I am assuming that the unit is in use and busy with normal system read/writes.
It should not be faster, not at all. A RAID 1 resilver should be able to do, even on the crappiest controllers, many RAID 1 rebuilds at wire speed all at once. The RAID card would not be a bottleneck, even with lots of drives going at the same time because there is effectively zero CPU overhead, it just passes straight from one drive to the other. So for example the reason you state, faster rebuilds, you do them all at once because you can rebuild two or more in the exact same time that you could do just one. There is no parity calculations, so the CPU on the RAID card remains effectively idle.
-
@wirestyle22 said in RAID10 - Two Drive Failure:
@JaredBusch said in RAID10 - Two Drive Failure:
I completely disagree. Reason stated above.This is a predictive failure, not a failure. You will get a faster resilver of each mirror by doing them individually.
Doesn't this put twice the amount of mileage on the array though? or no
No, I'm not sure what you mean exactly, but the answer is definitely no.
-
@scottalanmiller said in RAID10 - Two Drive Failure:
@JaredBusch said in RAID10 - Two Drive Failure:
@DustinB3403 said in RAID10 - Two Drive Failure:
@aaronstuder What raid controller do you have?
Exactly this. A real SMB system should be a hot plug. But we have no idea what you bought.
Even hot plug often requires you to offline a disk before you take it out for the system to be clear as to what is happening. ZFS is hot swap, but still requires that, for example.
I said it already, but hardware controllers in most systems have no interface to the OS in order to do anything. There is no way to offline a drive while running.