    • DashrenderD
      Dashrender @scottalanmiller
      last edited by

      @scottalanmiller said in Dell PERC Question (Server Down):

      @Dashrender said in Dell PERC Question (Server Down):

      @scottalanmiller said in Dell PERC Question (Server Down):

      @BRRABill said in Dell PERC Question (Server Down):

      @scottalanmiller

      Got it.

      So we're really just trying to avoid rebooting.

      Exactly, because if the server is still functional in any way (rebuilding) then rebooting puts the data at risk.

      Thanks, so I wasn't crazy for saying that last night.

      You aren't crazy for saying that.

      Never said I wasn't crazy in general.😂

      1 Reply Last reply Reply Quote 0
      • BRRABillB
        BRRABill
        last edited by

        I mean, in theory, the array has instructions for rebuilding, right?

        It has a plan of what to d, block by block. It just pauses on reboot.

        Now, if you unplugged it, yeah I could see an issue there.

        But isn't it possible it is smart enough to just pick back up?

        1 Reply Last reply Reply Quote 0
        • DashrenderD
          Dashrender
          last edited by

          Sure it is, but it is still a risk. And I've luckily never had to reboot while replacing a drive, different problem from you, so this has never come up fort me. My systems just stay up and running.

          1 Reply Last reply Reply Quote 1
          • BRRABillB
            BRRABill
            last edited by

            I did a few Google search. It seems like other places (including Adaptec) also say rebooting a rebuilding array is perfectly safe.

            Not arguing with anyone, just questioning why the people making the RAID hardware seem to think it is OK, but ML does not.

            http://blog.adaptec.com/2015/05/13/a-technical-issue-regarding-raid-buildrebuild/

            scottalanmillerS 1 Reply Last reply Reply Quote 0
            • scottalanmillerS
              scottalanmiller @BRRABill
              last edited by

              @BRRABill said in Dell PERC Question (Server Down):

              I did a few Google search. It seems like other places (including Adaptec) also say rebooting a rebuilding array is perfectly safe.

              Of course they do, you are reading their marketing.

              JaredBuschJ 1 Reply Last reply Reply Quote 0
              • scottalanmillerS
                scottalanmiller
                last edited by

                VMware advocates moving running workloads around, too. But you should fire anyone who did it in production based on that recommendation. I've seen people do that thinking that they would not get caught because "Vmware said it was safe" and brought down a bank because of it (hint: it wasn't safe.)

                1 Reply Last reply Reply Quote 0
                • JaredBuschJ
                  JaredBusch @scottalanmiller
                  last edited by

                  @scottalanmiller said in Dell PERC Question (Server Down):

                  @BRRABill said in Dell PERC Question (Server Down):

                  @scottalanmiller said

                  That means that the PERC has failed. That's a different issue.

                  Are we back to that?

                  I mean, it's definitely on the table. Just not sure why all of a sudden you think that's so likely.

                  Because you said that it was rebuilding. The PERC should remain up and viable even without disks attached to it. You can continue to manage it online through the iDRAC or a VM that isn't using those drives.

                  You do not manage Dell PERC through iDRAC or a VM.

                  1 Reply Last reply Reply Quote 0
                  • JaredBuschJ
                    JaredBusch @scottalanmiller
                    last edited by

                    @scottalanmiller said in Dell PERC Question (Server Down):

                    @BRRABill said in Dell PERC Question (Server Down):

                    I did a few Google search. It seems like other places (including Adaptec) also say rebooting a rebuilding array is perfectly safe.

                    Of course they do, you are reading their marketing.

                    I've done it many times over the years and never once had a failure. Yes it is a risk, but it is also adding downtime waiting for a rebuild to happen.

                    1 Reply Last reply Reply Quote 0
                    • scottalanmillerS
                      scottalanmiller
                      last edited by

                      Do you mean that the OMSA can't manage the PERC?

                      JaredBuschJ 1 Reply Last reply Reply Quote 0
                      • scottalanmillerS
                        scottalanmiller
                        last edited by

                        Does this not work for the iDRAC?

                        http://en.community.dell.com/techcenter/extras/m/white_papers/20438108/

                        1 Reply Last reply Reply Quote 0
                        • JaredBuschJ
                          JaredBusch @scottalanmiller
                          last edited by

                          @scottalanmiller said in Dell PERC Question (Server Down):

                          Do you mean that the OMSA can't manage the PERC?

                          The iDRAC is not OMSA they are different.

                          scottalanmillerS 1 Reply Last reply Reply Quote 0
                          • JaredBuschJ
                            JaredBusch
                            last edited by

                            OMSA can do things.

                            0_1461942333840_upload-fb5ada1a-9b6f-4708-b301-18cbbadd8d29

                            1 Reply Last reply Reply Quote 0
                            • JaredBuschJ
                              JaredBusch
                              last edited by

                              0_1461942372081_upload-ec59128b-1735-4fb7-8c39-fb04d03a5df7

                              1 Reply Last reply Reply Quote 0
                              • scottalanmillerS
                                scottalanmiller
                                last edited by

                                Right, using OMSA in the Dom0 should work fine for working with the PERC. Unless I've missed something.

                                JaredBuschJ 1 Reply Last reply Reply Quote 0
                                • JaredBuschJ
                                  JaredBusch @scottalanmiller
                                  last edited by

                                  @scottalanmiller said in Dell PERC Question (Server Down):

                                  Right, using OMSA in the Dom0 should work fine for working with the PERC. Unless I've missed something.

                                  Yes, but my point was you claimed to use iDRAC.

                                  scottalanmillerS 1 Reply Last reply Reply Quote 0
                                  • JaredBuschJ
                                    JaredBusch
                                    last edited by

                                    I was going to log into the iDRAC and get a screen there to show the difference, but for some reason it is not pulling an address..

                                    0_1461942723122_upload-40749dfc-edf0-4182-a0eb-8e7d168a38de

                                    1 Reply Last reply Reply Quote 0
                                    • JaredBuschJ
                                      JaredBusch
                                      last edited by

                                      You people need to quit making me work!

                                      BRRABillB 1 Reply Last reply Reply Quote 0
                                      • scottalanmillerS
                                        scottalanmiller @JaredBusch
                                        last edited by

                                        @JaredBusch said in Dell PERC Question (Server Down):

                                        @scottalanmiller said in Dell PERC Question (Server Down):

                                        Do you mean that the OMSA can't manage the PERC?

                                        The iDRAC is not OMSA they are different.

                                        The OMSA was in reference to managing via the Dom0.

                                        1 Reply Last reply Reply Quote 0
                                        • scottalanmillerS
                                          scottalanmiller @JaredBusch
                                          last edited by

                                          @JaredBusch said in Dell PERC Question (Server Down):

                                          @scottalanmiller said in Dell PERC Question (Server Down):

                                          Right, using OMSA in the Dom0 should work fine for working with the PERC. Unless I've missed something.

                                          Yes, but my point was you claimed to use iDRAC.

                                          I claimed both, but as two separate means of doing it.

                                          1 Reply Last reply Reply Quote 0
                                          • BRRABillB
                                            BRRABill
                                            last edited by

                                            That is what I was saying, that the iDRAC is pretty powerless with storage.

                                            I'll work on getting OMSA on the XS.

                                            scottalanmillerS 1 Reply Last reply Reply Quote 0