    Dell Perc H710 predicted failure

    Scheduled Pinned Locked Moved IT Discussion
    21 Posts 6 Posters 3.1k Views
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • scottalanmillerS
      scottalanmiller @dbeato
      last edited by

      @dbeato said in Dell Perc H710 predicted failure:

      @i3 said in Dell Perc H710 predicted failure:

      array to be degraded and rebuilt taking significantly longer to rebuild and being vulnerable while rebuilding.
      Wouldn’t the second option copy the data off just the drive in question then take the bad drive offline?

      A hotspare will do a rebuild still.

      Not always, hot spares don't always have the same clarity of action as a proper swap.

      1 Reply Last reply Reply Quote 0
      • scottalanmillerS
        scottalanmiller @i3
        last edited by

        @i3 said in Dell Perc H710 predicted failure:

        My understanding is the first option would involve the array to be degraded and rebuilt taking significantly longer to rebuild and being vulnerable while rebuilding.

        This situation happens either way. Only the proper first method fixes it faster than the unnecessary second method. The hot spare method has no advantages, just isn't quite as clear and moves your drives to weird positions (which is fine, but why?)

        1 Reply Last reply Reply Quote 1
        • scottalanmillerS
          scottalanmiller @i3
          last edited by

          @i3 said in Dell Perc H710 predicted failure:

          Wouldn’t the second option copy the data off just the drive in question then take the bad drive offline?

          No, that is not how a hot spare works. A hot spare is just sitting there doing nothing, waiting for a drive to fail.

          1 Reply Last reply Reply Quote 0
          • scottalanmillerS
            scottalanmiller @i3
            last edited by

            @i3 said in Dell Perc H710 predicted failure:

            Currently the virtual disk is still healthy and the predicted failure disk is still working. Option two seems like less risk and a quicker repair.

            It just feels this way, but this is incorrect.

            1 Reply Last reply Reply Quote 0
            • I
              i3
              last edited by

              Thank you for all the replies. I will proceed with the mark failed and swap.

              Thanks again!

              1 Reply Last reply Reply Quote 1
              • I
                i3
                last edited by

                Update: I had to clear the foreign config on the new drives, however, Open Manage would not display the "are you sure you want to clear the foreign config" message. It just went to a blank page. I had to uninstall OM and upgrade to the current version, then I was prompted about firmware and driver versions. To be safe I upgraded those as well, with reboots in between, took another system image failed the "bad drive" popped in a new one and the rebuild began. Completed in about 5 hours. All is working well.

                Thank again all.

                1 Reply Last reply Reply Quote 2
                • BRRABillB
                  BRRABill @JaredBusch
                  last edited by

                  @jaredbusch said in Dell Perc H710 predicted failure:

                  Don’t wait don’t delay just fucking do it

                  You should start making tshirts with this quote

                  JaredBuschJ 1 Reply Last reply Reply Quote 1
                  • JaredBuschJ
                    JaredBusch @BRRABill
                    last edited by

                    @brrabill said in Dell Perc H710 predicted failure:

                    @jaredbusch said in Dell Perc H710 predicted failure:

                    Don’t wait don’t delay just fucking do it

                    You should start making tshirts with this quote

                    Learn something today from your failure to reboot more did we?

                    BRRABillB 1 Reply Last reply Reply Quote 0
                    • BRRABillB
                      BRRABill @JaredBusch
                      last edited by

                      @jaredbusch said in Dell Perc H710 predicted failure:

                      @brrabill said in Dell Perc H710 predicted failure:

                      @jaredbusch said in Dell Perc H710 predicted failure:

                      Don’t wait don’t delay just fucking do it

                      You should start making tshirts with this quote

                      Learn something today from your failure to reboot more did we?

                      Not really.

                      Wouldn't have helped. Would have just messed up whatever weekend i did it on.

                      1 Reply Last reply Reply Quote 0
                      • BRRABillB
                        BRRABill
                        last edited by

                        Still in favor of tshirts, however.

                        1 Reply Last reply Reply Quote 1