Solved RAID - Two Arrays for Server? Array 1 for Windows Host and Array 2 for VMs and Data?
-
@Pete-S said in RAID - Two Arrays for Server? Array 1 for Windows Host and Array 2 for VMs and Data?:
This is what we do.
Option 3.
Hypervisor on satadom or small SSD drive.
Performance storage array with SSDs. Raid 1 or 10.
Capacity storage array with 3.5" HDDs. Raid 1 or 10.- Each VMs gets the kind of storage it needs.
- RAID1 is default for the arrays.
- RAID10 is only used when the capacity is needed (always as few drives as possible).
Right now I'm prepping a RAID 1 array 2x16TB that will go into one of our hosts.
md4 : active raid1 sdm[1] sdl[0] 15625748288 blocks super 1.2 [2/2] [UU] [>....................] resync = 0.6% (99811008/15625748288) finish=1322.2min speed=195699K/sec
We'll see how long it takes. Supposedly around 23 hours.
Same here.
-
@scottalanmiller said in RAID - Two Arrays for Server? Array 1 for Windows Host and Array 2 for VMs and Data?:
@Pete-S said in RAID - Two Arrays for Server? Array 1 for Windows Host and Array 2 for VMs and Data?:
This is what we do.
Option 3.
Hypervisor on satadom or small SSD drive.
Performance storage array with SSDs. Raid 1 or 10.
Capacity storage array with 3.5" HDDs. Raid 1 or 10.- Each VMs gets the kind of storage it needs.
- RAID1 is default for the arrays.
- RAID10 is only used when the capacity is needed (always as few drives as possible).
Right now I'm prepping a RAID 1 array 2x16TB that will go into one of our hosts.
md4 : active raid1 sdm[1] sdl[0] 15625748288 blocks super 1.2 [2/2] [UU] [>....................] resync = 0.6% (99811008/15625748288) finish=1322.2min speed=195699K/sec
We'll see how long it takes. Supposedly around 23 hours.
Same here.
So you've moved to SSD with RAID 1 or RAID 10, no more RAID 5?