    ER-X firmware Upgrade

    IT Discussion
    8
    27
    2.9k
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • JaredBuschJ
      JaredBusch @pmoncho
      last edited by

      @pmoncho said in ER-X firmware Upgrade:

      Can I go directly to v2.0.9-hotfix.2? Are the hotfix's cumulative?

      Yes and yes.

      1 Reply Last reply Reply Quote 1
      • pmonchoP
        pmoncho
        last edited by

        Tried to update this afternoon and it all went south.
        ER-x = 10.10.2.1

        Rebooted ER-x first, confirmed all was well (I was updating my PC also), connected to ER-X GUI, Downloaded backup and uploaded 2.0.9 Hotifx 2.

        It sat there and spun (GUI uploading file) for about 30 minutes and figure something went south.

        Lost connection to GUI, could not ping, timed out trying to get to GUI. Seemed I had no choice but to unplug POE (using POE injector) and tried to reboot. No luck.

        ETH0 (WAN) port, ETH2 (Netgear Switch) and ETH4 POE (UAP Lite) were lit.
        I had no Internet but I could ping the Netgear switch and UAP Lite and DHCP is no longer working.

        I then decided to try the Reset button but that is not working either. While ERX is on, used paperclip, held for 20+ seconds, no change, eth4 light did not blink or become solid and router did not reboot.

        Unplug ERX, press Reset while plugging in POE, ETH4 would blink but the router would not reboot after that.

        I could not ping either 192.168.1.1 or 10.10.2.1 and setting my IP to 10.10.2.88/192.168.1.5 if I was plugged into any ETH port or LAN port on POE injector.

        Anybody else run into this?
        Is the ER-X "Bricked?"

        I went out and bought a cheap D-link to get me through as the wife needs to WFH. I will play with the ER-x tomorrow at work if anyone has any ideas.

        notverypunnyN 1 Reply Last reply Reply Quote 0
        • notverypunnyN
          notverypunny @pmoncho
          last edited by

          @pmoncho I don't think it's bricked, but I seem to recall problems when going from the 1 series to 2... IIRC part of the problem might be that the button inside that pinhole for the paperclip reset is a bugger to actually hit and hold... I can't say with 100% certainty whether it was the ER-X or one of my dd-wrt projects that I ended up having to hold the paperclip / pinhole reset for something crazy like 5 minutes for things to play nice.

          pmonchoP 1 Reply Last reply Reply Quote 0
          • pmonchoP
            pmoncho @notverypunny
            last edited by

            @notverypunny said in ER-X firmware Upgrade:

            @pmoncho I don't think it's bricked, but I seem to recall problems when going from the 1 series to 2... IIRC part of the problem might be that the button inside that pinhole for the paperclip reset is a bugger to actually hit and hold... I can't say with 100% certainty whether it was the ER-X or one of my dd-wrt projects that I ended up having to hold the paperclip / pinhole reset for something crazy like 5 minutes for things to play nice.

            Thanks. I will try that today. I must have done that reset button 30+ times so far but will give it a try.

            1 Reply Last reply Reply Quote 0
            • M
              marcinozga
              last edited by

              It probably is bricked. The same happened to my ER-X when firmware 2 came out. I got it booted eventually over serial cable, and if I remember correctly it displayed something about internal storage.

              pmonchoP 1 Reply Last reply Reply Quote 0
              • pmonchoP
                pmoncho @marcinozga
                last edited by

                @marcinozga said in ER-X firmware Upgrade:

                It probably is bricked. The same happened to my ER-X when firmware 2 came out. I got it booted eventually over serial cable, and if I remember correctly it displayed something about internal storage.

                I noticed others have had the same issue in the past.

                I just saw the serial connection setup. Did you just use the USB-TTL device to connect?

                The part that bugs me is I had check the storage issue prior to upgrade. Had 58% free so I figured I would be ok.

                DashrenderD JaredBuschJ M 3 Replies Last reply Reply Quote 0
                • DashrenderD
                  Dashrender @pmoncho
                  last edited by

                  @pmoncho said in ER-X firmware Upgrade:

                  @marcinozga said in ER-X firmware Upgrade:

                  It probably is bricked. The same happened to my ER-X when firmware 2 came out. I got it booted eventually over serial cable, and if I remember correctly it displayed something about internal storage.

                  I noticed others have had the same issue in the past.

                  I just saw the serial connection setup. Did you just use the USB-TTL device to connect?

                  The part that bugs me is I had check the storage issue prior to upgrade. Had 58% free so I figured I would be ok.

                  yeah, that's not much when the firmware is 70 MB compressed.

                  pmonchoP 1 Reply Last reply Reply Quote 0
                  • pmonchoP
                    pmoncho @Dashrender
                    last edited by

                    @dashrender said in ER-X firmware Upgrade:

                    @pmoncho said in ER-X firmware Upgrade:

                    @marcinozga said in ER-X firmware Upgrade:

                    It probably is bricked. The same happened to my ER-X when firmware 2 came out. I got it booted eventually over serial cable, and if I remember correctly it displayed something about internal storage.

                    I noticed others have had the same issue in the past.

                    I just saw the serial connection setup. Did you just use the USB-TTL device to connect?

                    The part that bugs me is I had check the storage issue prior to upgrade. Had 58% free so I figured I would be ok.

                    yeah, that's not much when the firmware is 70 MB compressed.

                    I definitely know that now. lol If that is what did it. The other reports I read, before I did anything, user mentioned <40%. I decided to give it a shot. Oh well. Bought a cheap D-link at Microcenter yesterday to get us going. Glad I did as we are locked down with snow this morning in NE Ohio.

                    1 Reply Last reply Reply Quote 0
                    • pmonchoP
                      pmoncho
                      last edited by

                      @dashrender said in ER-X firmware Upgrade:

                      @pmoncho said in ER-X firmware Upgrade:

                      @marcinozga said in ER-X firmware Upgrade:

                      It probably is bricked. The same happened to my ER-X when firmware 2 came out. I got it booted eventually over serial cable, and if I remember correctly it displayed something about internal storage.

                      I noticed others have had the same issue in the past.

                      I just saw the serial connection setup. Did you just use the USB-TTL device to connect?

                      The part that bugs me is I had check the storage issue prior to upgrade. Had 58% free so I figured I would be ok.

                      yeah, that's not much when the firmware is 70 MB compressed.

                      I definitely know that now. lol If that is what did it. The other reports I read, before I did anything, user mentioned <40%. I decided to give it a shot. Oh well.

                      Bought a cheap D-link at Microcenter yesterday to get us going. Glad I did as we are locked down with snow this morning in NE Ohio.

                      1 Reply Last reply Reply Quote 0
                      • DashrenderD
                        Dashrender
                        last edited by

                        I'm thinking if you can get a console cable you should be able to recover this device.

                        1 Reply Last reply Reply Quote 0
                        • notverypunnyN
                          notverypunny
                          last edited by notverypunny

                          There's mention of a tftp recovery option in the link below:

                          https://community.ui.com/questions/EdgeRouter-X-bricked-after-factory-reset/12c82f1b-8fd1-47ec-9a92-88ec81ea208b

                          Don't know if it still applies but might be worth trying.

                          Also:
                          https://help.ui.com/hc/en-us/articles/360018189493-EdgeRouter-Manual-TFTP-Recovery#4

                          and
                          https://help.ui.com/hc/en-us/articles/360019289113

                          pmonchoP 1 Reply Last reply Reply Quote 0
                          • pmonchoP
                            pmoncho @notverypunny
                            last edited by

                            @notverypunny said in ER-X firmware Upgrade:

                            There's mention of a tftp recovery option in the link below:

                            https://community.ui.com/questions/EdgeRouter-X-bricked-after-factory-reset/12c82f1b-8fd1-47ec-9a92-88ec81ea208b

                            Don't know if it still applies but might be worth trying.

                            Also:
                            https://help.ui.com/hc/en-us/articles/360018189493-EdgeRouter-Manual-TFTP-Recovery#4

                            and
                            https://help.ui.com/hc/en-us/articles/360019289113

                            I was looking at similar posts. I think I will look into the USB-TTL device.

                            Some posts mention 3.3v and other mention +5v - Something tells me it matter but I am dumb in these matters.

                            DashrenderD 1 Reply Last reply Reply Quote 0
                            • DashrenderD
                              Dashrender @pmoncho
                              last edited by

                              @pmoncho said in ER-X firmware Upgrade:

                              @notverypunny said in ER-X firmware Upgrade:

                              There's mention of a tftp recovery option in the link below:

                              https://community.ui.com/questions/EdgeRouter-X-bricked-after-factory-reset/12c82f1b-8fd1-47ec-9a92-88ec81ea208b

                              Don't know if it still applies but might be worth trying.

                              Also:
                              https://help.ui.com/hc/en-us/articles/360018189493-EdgeRouter-Manual-TFTP-Recovery#4

                              and
                              https://help.ui.com/hc/en-us/articles/360019289113

                              I was looking at similar posts. I think I will look into the USB-TTL device.

                              Some posts mention 3.3v and other mention +5v - Something tells me it matter but I am dumb in these matters.

                              wait - what? there's voltage concerns on a USB to terminal connection? Can't say I've ever seen that.

                              pmonchoP 1 Reply Last reply Reply Quote 0
                              • pmonchoP
                                pmoncho @Dashrender
                                last edited by

                                @dashrender said in ER-X firmware Upgrade:

                                @pmoncho said in ER-X firmware Upgrade:

                                @notverypunny said in ER-X firmware Upgrade:

                                There's mention of a tftp recovery option in the link below:

                                https://community.ui.com/questions/EdgeRouter-X-bricked-after-factory-reset/12c82f1b-8fd1-47ec-9a92-88ec81ea208b

                                Don't know if it still applies but might be worth trying.

                                Also:
                                https://help.ui.com/hc/en-us/articles/360018189493-EdgeRouter-Manual-TFTP-Recovery#4

                                and
                                https://help.ui.com/hc/en-us/articles/360019289113

                                I was looking at similar posts. I think I will look into the USB-TTL device.

                                Some posts mention 3.3v and other mention +5v - Something tells me it matter but I am dumb in these matters.

                                wait - what? there's voltage concerns on a USB to terminal connection? Can't say I've ever seen that.

                                The ER-X doesn't have a console port so you have to open it up, use a USB-TTL to connect to the serial port PINs on the board.

                                DashrenderD 1 Reply Last reply Reply Quote 0
                                • DashrenderD
                                  Dashrender @pmoncho
                                  last edited by

                                  @pmoncho said in ER-X firmware Upgrade:

                                  @dashrender said in ER-X firmware Upgrade:

                                  @pmoncho said in ER-X firmware Upgrade:

                                  @notverypunny said in ER-X firmware Upgrade:

                                  There's mention of a tftp recovery option in the link below:

                                  https://community.ui.com/questions/EdgeRouter-X-bricked-after-factory-reset/12c82f1b-8fd1-47ec-9a92-88ec81ea208b

                                  Don't know if it still applies but might be worth trying.

                                  Also:
                                  https://help.ui.com/hc/en-us/articles/360018189493-EdgeRouter-Manual-TFTP-Recovery#4

                                  and
                                  https://help.ui.com/hc/en-us/articles/360019289113

                                  I was looking at similar posts. I think I will look into the USB-TTL device.

                                  Some posts mention 3.3v and other mention +5v - Something tells me it matter but I am dumb in these matters.

                                  wait - what? there's voltage concerns on a USB to terminal connection? Can't say I've ever seen that.

                                  The ER-X doesn't have a console port so you have to open it up, use a USB-TTL to connect to the serial port PINs on the board.

                                  Oh yeah - One of the reasons JB disliked this device!

                                  pmonchoP 1 Reply Last reply Reply Quote 0
                                  • pmonchoP
                                    pmoncho @Dashrender
                                    last edited by

                                    @dashrender said in ER-X firmware Upgrade:

                                    @pmoncho said in ER-X firmware Upgrade:

                                    @dashrender said in ER-X firmware Upgrade:

                                    @pmoncho said in ER-X firmware Upgrade:

                                    @notverypunny said in ER-X firmware Upgrade:

                                    There's mention of a tftp recovery option in the link below:

                                    https://community.ui.com/questions/EdgeRouter-X-bricked-after-factory-reset/12c82f1b-8fd1-47ec-9a92-88ec81ea208b

                                    Don't know if it still applies but might be worth trying.

                                    Also:
                                    https://help.ui.com/hc/en-us/articles/360018189493-EdgeRouter-Manual-TFTP-Recovery#4

                                    and
                                    https://help.ui.com/hc/en-us/articles/360019289113

                                    I was looking at similar posts. I think I will look into the USB-TTL device.

                                    Some posts mention 3.3v and other mention +5v - Something tells me it matter but I am dumb in these matters.

                                    wait - what? there's voltage concerns on a USB to terminal connection? Can't say I've ever seen that.

                                    The ER-X doesn't have a console port so you have to open it up, use a USB-TTL to connect to the serial port PINs on the board.

                                    Oh yeah - One of the reasons JB disliked this device!

                                    Yep. Bummer. I found this on Amazon:
                                    https://www.amazon.com/gp/product/B07WX2DSVB/ref=ppx_yo_dt_b_asin_title_o00_s00?ie=UTF8&psc=1

                                    Someone already used it on an ER so hopefully it will work for me too.

                                    JaredBuschJ 1 Reply Last reply Reply Quote 0
                                    • JaredBuschJ
                                      JaredBusch @pmoncho
                                      last edited by

                                      @pmoncho said in ER-X firmware Upgrade:

                                      @dashrender said in ER-X firmware Upgrade:

                                      @pmoncho said in ER-X firmware Upgrade:

                                      @dashrender said in ER-X firmware Upgrade:

                                      @pmoncho said in ER-X firmware Upgrade:

                                      @notverypunny said in ER-X firmware Upgrade:

                                      There's mention of a tftp recovery option in the link below:

                                      https://community.ui.com/questions/EdgeRouter-X-bricked-after-factory-reset/12c82f1b-8fd1-47ec-9a92-88ec81ea208b

                                      Don't know if it still applies but might be worth trying.

                                      Also:
                                      https://help.ui.com/hc/en-us/articles/360018189493-EdgeRouter-Manual-TFTP-Recovery#4

                                      and
                                      https://help.ui.com/hc/en-us/articles/360019289113

                                      I was looking at similar posts. I think I will look into the USB-TTL device.

                                      Some posts mention 3.3v and other mention +5v - Something tells me it matter but I am dumb in these matters.

                                      wait - what? there's voltage concerns on a USB to terminal connection? Can't say I've ever seen that.

                                      The ER-X doesn't have a console port so you have to open it up, use a USB-TTL to connect to the serial port PINs on the board.

                                      Oh yeah - One of the reasons JB disliked this device!

                                      Yep. Bummer. I found this on Amazon:
                                      https://www.amazon.com/gp/product/B07WX2DSVB/ref=ppx_yo_dt_b_asin_title_o00_s00?ie=UTF8&psc=1

                                      Someone already used it on an ER so hopefully it will work for me too.

                                      I have a USB cable (not the one you linked) that I use for ER-X recovery. Same process as ERL and such.

                                      1 Reply Last reply Reply Quote 0
                                      • JaredBuschJ
                                        JaredBusch @pmoncho
                                        last edited by

                                        @pmoncho said in ER-X firmware Upgrade:

                                        The part that bugs me is I had check the storage issue prior to upgrade. Had 58% free so I figured I would be ok.

                                        At some point, Ubiquiti updated the firmware upgrade process of the ER-X to pre-delete the old version. I have no idea what "space" should be available, but I always deleted the backup firmware prior to upgrading until I was on the 2.X line.

                                        This has been a known issue with the ER-X from day 1.

                                        pmonchoP 1 Reply Last reply Reply Quote 3
                                        • CloudKnightC
                                          CloudKnight
                                          last edited by

                                          Glad I didn't get this issue when I upgraded to the latest version.

                                          pmonchoP 1 Reply Last reply Reply Quote 0
                                          • pmonchoP
                                            pmoncho @JaredBusch
                                            last edited by

                                            @jaredbusch said in ER-X firmware Upgrade:

                                            @pmoncho said in ER-X firmware Upgrade:

                                            The part that bugs me is I had check the storage issue prior to upgrade. Had 58% free so I figured I would be ok.

                                            At some point, Ubiquiti updated the firmware upgrade process of the ER-X to pre-delete the old version. I have no idea what "space" should be available, but I always deleted the backup firmware prior to upgrading until I was on the 2.X line.

                                            This has been a known issue with the ER-X from day 1.

                                            I have now updated my upgrade process. Backup config, confirm download of currently loaded firmware is available, reboot, delete backup firmware, update firmware.

                                            JaredBuschJ 1 Reply Last reply Reply Quote 0