ML
    • Recent
    • Categories
    • Tags
    • Popular
    • Users
    • Groups
    • Register
    • Login

    Xenserver 7 UPS monitoring

    IT Discussion
    8
    28
    7.0k
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • BRRABillB
      BRRABill @scottalanmiller
      last edited by

      @scottalanmiller said in Xenserver 7 UPS monitoring:

      @BRRABill said in Xenserver 7 UPS monitoring:

      @scottalanmiller are any of the Eaton peeps still here?

      Haven't seen them, maybe @Minion-Queen knows?

      Yeah, me either, which is why I asked.

      1 Reply Last reply Reply Quote 0
      • T
        tiagom @BRRABill
        last edited by tiagom

        @BRRABill said in Xenserver 7 UPS monitoring:

        rts xenserver

        According to this

        http://lit.powerware.com/ll_download.asp?file=IPSS-UPS-Connectivity-Compatibility-List-June2016.pdf

        it does over usb.

        Nope im wrong.Only UPS Companion is supported.

        BRRABillB 1 Reply Last reply Reply Quote 0
        • BRRABillB
          BRRABill @tiagom
          last edited by

          @tiagom said in Xenserver 7 UPS monitoring:

          @BRRABill said in Xenserver 7 UPS monitoring:

          rts xenserver

          According to this

          http://lit.powerware.com/ll_download.asp?file=IPSS-UPS-Connectivity-Compatibility-List-June2016.pdf

          it does over usb.

          Nope im wrong.Only UPS Companion is supported.

          Yes, exactly the issue.

          T 1 Reply Last reply Reply Quote 0
          • T
            tiagom @BRRABill
            last edited by

            @BRRABill what about using http://networkupstools.org/index.html

            It supports the eaton 5s
            http://networkupstools.org/stable-hcl.html?manufacturer=Eaton&model=3S

            It should be in the Epel repo.

            1 Reply Last reply Reply Quote 0
            • travisdh1T
              travisdh1 @BRRABill
              last edited by

              @BRRABill We ended up with a 5C I think, great stuff for the price. So long as you can get it connected (usb/serial), you should be able to use apcupsd to monitor it. Eaton does have software available for Linux, but the one I installed is only monitoring and a GUI (I have it installed on one of the virtual machines.)

              M 1 Reply Last reply Reply Quote 0
              • M
                mazterjedi @travisdh1
                last edited by

                So, both of my UPS's have both USB and serial ports. If I were to connect the UPS's to the xenservers via serial, is there a way to establish comms? What about a USB to IP converter? My concern is that although I think I would be able to tell the VMs to shut down in a power failure, how would I tell the servers themselves? I know a power failure is a sure way to hose a RAID array. Since the array was created by Xen, it is fully software managed.

                DashrenderD travisdh1T scottalanmillerS 3 Replies Last reply Reply Quote 0
                • DashrenderD
                  Dashrender @mazterjedi
                  last edited by

                  @mazterjedi said in Xenserver 7 UPS monitoring:

                  So, both of my UPS's have both USB and serial ports. If I were to connect the UPS's to the xenservers via serial, is there a way to establish comms? What about a USB to IP converter? My concern is that although I think I would be able to tell the VMs to shut down in a power failure, how would I tell the servers themselves? I know a power failure is a sure way to hose a RAID array. Since the array was created by Xen, it is fully software managed.

                  You're running a local software only RAID? why not RAID controller?

                  1 Reply Last reply Reply Quote 0
                  • travisdh1T
                    travisdh1 @mazterjedi
                    last edited by

                    @mazterjedi You can have one of the vm's run

                    ssh user@xenserverip sudo poweroff
                    

                    XenServer will take the time to gracefully power down all the VMs currently running on the host. So long as you don't just force power off on the host, it should work.

                    The only problems I've had with this are guests that don't shut down properly. Like @scottalanmiller says, it's important to reboot just as a test if nothing else.

                    1 Reply Last reply Reply Quote 0
                    • scottalanmillerS
                      scottalanmiller @mazterjedi
                      last edited by

                      @mazterjedi said in Xenserver 7 UPS monitoring:

                      So, both of my UPS's have both USB and serial ports. If I were to connect the UPS's to the xenservers via serial, is there a way to establish comms? What about a USB to IP converter? My concern is that although I think I would be able to tell the VMs to shut down in a power failure, how would I tell the servers themselves? I know a power failure is a sure way to hose a RAID array. Since the array was created by Xen, it is fully software managed.

                      Yup, Linux can read comms just fine and anything that Linux can see, the Dom0 (XenServer control) can see. It would be a problem if you wanted the VMs to see this. But not a problem for XenServer to see it.

                      1 Reply Last reply Reply Quote 1
                      • DustinB3403D
                        DustinB3403
                        last edited by

                        Obviously HA functionality which would start the VM's has to be disabled as well.

                        Otherwise you'll end up in a loop with the system trying to power off the VM's until your UPS loses power.

                        BRRABillB 1 Reply Last reply Reply Quote 1
                        • BRRABillB
                          BRRABill @DustinB3403
                          last edited by

                          @DustinB3403 said in Xenserver 7 UPS monitoring:

                          Obviously HA functionality which would start the VM's has to be disabled as well.

                          Otherwise you'll end up in a loop with the system trying to power off the VM's until your UPS loses power.

                          That would be bad, mmmmm'k.